EasyManua.ls Logo

Toshiba e-STUDIO6520c - Error in Internet FAX; Scanning Function

Toshiba e-STUDIO6520c
648 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
© 2008-2011 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530C
ERROR CODE and TROUBLESHOOTING
6 - 127
[F200] Data overwrite option (GP-1070) disabled
Perform firmware installation (all firmware: OS, HDD, SYS, PFC Firmware, Engine Main Firmware, and
Scanner Firmware) with the USB media.
* When the function of the Data Overwrite option (GP-1070) is deleted from the equipment, the
service call “F200” occurs.
6.2.23 Error in Internet FAX / Scanning Function
Notes:
1. When initializing the Electronic Filing (Setting Mode (08-666)), all data in the Electronic Filing
are erased. Back up the data in the Electronic Filing by using the Electronic Filing Function of
TopAccess before the initialization.
2. When initializing the shared folder (Setting Mode (08-667)), all data in the shared folder are
erased. Back up the data in the shared folder by using Explorer before the initialization.
3. When formatting the HDD (Setting Mode (08-690)), all data in the shared folder, Electronic
Filing, Address Book, template, etc. are erased. Back up these data before the initialization.
Note that some of data cannot be backed up.
P.7-22 "7.2.3 Precautions and procedures when replacing the HDD"
[ 1 ] Internet FAX related error
[1C10] System access abnormality
[1C32] File deletion failure
Turn the power OFF and then back ON. Perform the job in error again.
If the error still occurs, first, check if there are no jobs existing and then perform the HDD formatting
(08-690).
[1C11] Insufficient memory
When there are running jobs, perform the job in error again after the completion of the running jobs.
If the error still occurs, turn the power OFF and then back ON, and perform the job again.
[1C12] Message reception error
[1C13] Message transmission error
Turn the power OFF and then back ON. Perform the job in error again.
[1C14] Invalid parameter
When a template is used, form the template again.
If the error still occurs, turn the power OFF and then back ON, and perform the job again.
[1C15] Exceeding file capacity
Reset and extend the “Maximum send to E-mail/iFAX size” or reduce the number of pages and
perform the job again.
[1C20] System management module access abnormality
[1C21] Job control module access abnormality
[1C22] Job control module access abnormality
Turn the power OFF and then back ON. Perform the job in error again.
Check if there are no other running jobs and perform the HDD formatting (08-690).
If the recovery is still not completed, replace the SYS board.

Table of Contents

Other manuals for Toshiba e-STUDIO6520c

Related product manuals