ERROR CODE and TROUBLESHOOTING
6 - 76
[C1A0] LCF end fence motor abnormality
[C1C0] Option LCF tray-up motor abnormality
(1) Is the option LCF tray motor working?
(2) Is the option LCF tray up sensor working?
(3) Replace the tray motor.
(4) Replace the tray up sensor.
(5) Replace the option LCF board.
Is the LCF end fence motor working? (Perform the output check: 03-256)
|
|
|
|
|
|
|
|
È
NO Æ 1. Check if the connector of the LCF end fence motor is disconnected.
2. Check if the connector CN507 on the PFC board is disconnected.
3. Check if the connector pins are disconnected or the harnesses are open
circuited.
4. Check if the conductor patterns on the PFC board is short circuited or open
circuited.
5. Replace the LCF end fence motor.
6. Replace the PFC board.
YES
Are the LCF end fence home/stop position sensors working?
(Perform the input check: 03-[Copy ON]/[9]/[E], [Scan ON /[1]/[E])
|
|
|
|
|
|
|
|
|
È
NO Æ 1. Check if the connectors of the sensors are disconnected.
2. Check if the connector CN507 on the LGC board is disconnected.
3. Check if the slit reaches the sensors.
4. Check if the connector pins are disconnected or the harnesses are open
circuited.
5. Check if the conductor patterns on the PFC board is short circuited or open
circuited.
6. Replace the sensors.
7. Replace the PFC board.
YES
1. Check if the conductor pattern on the PFC board is short circuited or open circuited.
2. Replace the PFC board.