e-STUDIO5520C/6520C/6530C © 2008-2011 TOSHIBA TEC CORPORATION All rights reserved
SELF-DIAGNOSTIC MODE
2 - 20
*4
Do not let the sub-hopper toner motors rotate in reverse when toner cartridges are installed because
the cartridges will become locked.
For e-STUDIO6530c only
468 Lower exit section cooling fan-3 ON/OFF 3
470 Automatic power OFF at fuser unit temperature abnormality 4
Code Function Code Function Procedure
503 Polygonal motor (600dpi) ON 553 Code No.503 function OFF 1
510 Drum motor-K ON
(Operation available without the
process unit)
560 Code No.510 function OFF 1(*5)
511 Drum motor-YMC ON
(Operation available without the
process unit)
561 Code No.511 function OFF 1(*5)
512 Developer unit motor-K ON
(Operation available without the
process unit)
562 Code No.512 function OFF 1
513 Developer unit motor-YMC ON
(Operation available without the
process unit)
563 Code No.513 function OFF 1
516 Transfer belt motor ON
(Operation available without the
process unit)
566 Code No.516 function OFF 1(*6)
519 2nd transfer motor ON 569 Code No.519 function OFF 1(*7)
520 Feed motor (normal rotation) ON
(Paper fed from 1st drawer)
570 Code No.520 function OFF 1
521 Feed motor (reverse rotation) ON
(Paper fed from 2nd drawer)
571 Code No.521 function OFF 1
522 Feed/transport motor ON 572 Code No.522 function OFF 1
523 Tandem LCF feed motor ON 573 Code No.523 function OFF 1
524 Transport motor-1 ON 574 Code No.524 function OFF 1
525 Transport motor-2 ON 575 Code No.525 function OFF 1
526 Bypass motor ON 576 Code No.526 function OFF 1
527 Option LCF transport motor ON 577 Code No.527 function OFF 1
528 Registration motor ON 578 Code No.528 function OFF 1
529 Fuser motor (normal rotation) ON 579 Code No.529 function OFF 1
530 Bridge unit transport entrance motor
ON
580 Code No.530 function OFF 1
532 Reverse motor (normal rotation) ON 582 Code No.532 function OFF 1
534 Reverse motor (reverse rotation) ON 584 Code No.534 function OFF 1
536 Bridge unit transport exit motor (normal
rotation) ON
(lower exit tray direction)
586 Code No.536 function OFF 1
538 Bridge unit transport exit motor
(reverse rotation) ON
(upper exit tray direction)
588 Code No.538 function OFF 1
540 Exit motor (normal rotation) ON
(lower exit tray direction)
590 Code No.540 function OFF 1
542 Exit motor (reverse rotation) ON
(upper exit tray direction)
592 Code No.542 function OFF 1
544 ADU motor-2 ON 594 Code No.544 function OFF 1
546 ADU motor-1 ON 596 Code No.546 function OFF 1
Code Function Procedure