EasyManua.ls Logo

Toshiba e-STUDIO6520c - Page 583

Toshiba e-STUDIO6520c
648 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
© 2008-2011 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530C
FIRMWARE UPDATING
8 - 19
(5) Select “6. MEP Firmware Update” with the digital keys.
“*” is displayed next to the selected item. Display or delete the “*” by pressing the number of the
item.
(6) Press the [START] button.
Updating starts and the processing status is displayed on the LCD screen.
(7) “Update Completed.” is displayed at the bottom of the LCD screen after the updating is
completed properly.
Fig. 8-11
Notes:
“Update Failed.” is displayed at the bottom of the LCD screen when the updating is not
completed properly. “Failed” appears next to the failed item on the status display. Even if
though an update fails, do not turn the power OFF until all other updates are finished. If
"Update Failed" appears at the bottom of the screen, turn OFF the power and then check the
following items. After confirming and clearing the problems, restart updating from the
beginning.
- Do the USB media meet the conditions to be used for updating?
- Is the data file written properly on the USB media?
- Are the USB media installed properly?
- Do the USB media and equipment operate properly?
When an error occurred and the update failed, “Update Failed” or “Failed” appears on the
screen and an error code appears next to the message. The content of each error code is
shown below.
(8) Press the [ON/OFF] button to shut down the equipment, and then remove the USB media.
Item Remarks
6. MEP Firmware Update Updating the Imaging Acceleration Board ROM
Status display during update Status display when update is completed
MEP Firm Update .......... SROM Update MEP Firm Update .......... Completed
Imaging Acceleration Board update Error
Error number Error message Error content
I01 Board Error The MEP board is not operating properly.
I02 Parameter Error The parameter for API function is incorrect.
I03
File Read Failed An error occurred during a file input
operation.
I04
Temporary File Error An error occurred during a temporary file
operation.
I05 File Format Error The format of the input file is incorrect.
I06
Memory Allocation Failed An error occurred during the memory
allocation.
I00 Other error Other error

Table of Contents

Other manuals for Toshiba e-STUDIO6520c

Related product manuals