Technology Modules
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
434
:
Byte 2
Bit 0
Word 1
Bit 0
Byte 1
Bit 0 transmission rate
Bit 1 Bit 1 Bit 1
Bit 2 Bit 2 Bit 2
Bit 3 Bit 3 Bit 3
Bit 4 Bit 4 Bit 4 reserved
Bit 5 Bit 5 Bit 5
Bit 6 Bit 6 Bit 6
Bit 7 Bit 7 Bit 7
Byte 3
Bit 0 Bit 8
Byte 0
Bit 0 Data frame bits
Bit 1 Bit 9 Bit 1
Bit 2 Bit 10 Bit 2
Bit 3 Bit 11 Bit 3
Bit 4 Bit 12 Bit 4
Bit 5 Bit 13 Bit 5
Bit 6 Bit 14 Bit 6 reserved
Bit 7 Bit 15 Bit 7 Data format
Parameter name Value
Sensor
Sensor idle data
test
activate ZERO test of data cable.
Deactivate web server After the last valid bit, a ZERO test of the data cable is
not carried out.
Number of invalid bits
(LSB)
0…15 Number of invalid bits on the LSB side of the position
value supplied by the SSI encoder.
The meaningful word width of the position value trans-
ferred to the module bus master is as follows:
SSI_FRAME_LEN - INVALID_BITS_MSB-
INVALID_BITS_LSB.
The invalid bits on the LSB side are removed by shifting
the position value to the right,
starting with the LSB.
(Default 0 bit = 0× 0).
INVALID_BITS_MSB +INVALID_BITS_LSB must always
be less than SSI_FRAME_LEN.
Standard
PROFIBUS
PROFINET
Parameters
byte-
oriented
word-
oriented