435
2020/09
Invalid bits (MSB) 0…7 Number of invalid bits on the MSB side of the position
value supplied by the SSI encoder. The meaningful
word width of the position value transferred to the
module bus master is as follows:
SSI_FRAME_LEN - INVALID_BITS_MSB -
INVALID_BITS_LSB.
Number of invalid bits on the MSB side of the position
value supplied by the SSI encoder.
INVALID_BITS_MSB +INVALID_BITS_LSB must always
be less than SSI_FRAME_LEN.
Default: 0 = 0hex
transmission rate 1000000 bps
500000 bps
250000 bps
125000 bps
100000 bps
83000 bps
71000 bps
62500 bps
Number of
data frame bits
1…32 Number of bits of the SSI data frame. SSI_FRAME_LEN
must always be greater than INVALID_BITS.
Default: 25 = 19hex
Data format Binary coded SSI encoder sends data in binary code
GRAY coded SSI encoder sends data in GRAY code
Parameter name Value