# at the beginning of a line indicates a comment.
These are used for internal documentation. If you make changes, comment them, for
example:
# TTL I/O on J7
#
# Modification by REP on 2 Apr 03
# Added new interlock input on connector panel J7 pin07
...
The top part of the file provides a list of internal variables names that are used to define
the logical interface to the softplane.
These are divided into status inputs (also called indicators) and control outputs (also
called requests).
For example, sPedAZ0 corresponds to the LSB of a digital azimuth angle relative to the
antenna pedestal. The following tables provide a summary of the available status and
control variable names.
Important: This table is subject to change
Each definition line in the file starts with the keyword text:
# splConfig...
RVP900 User Guide M211322EN-J