DIAGNOSTICS
Vertical Express Product Manual 3-39 88500 v.1.0
Diagnostics Section Control System Fault Codes
This manual shows only the parameters that have an operational relevance to the ICON32. The UIT may have
additional parameters available, which should not effect the controller operation.
1110 A17/B44 shutdown error - Inspection to reset.
• An input and its respective monitor indicates a logically
impossible condition or failure; Top and bottom final limits
active at the same time.
1111 Indicates that the seismic sensor has been activated. —
1113 Car service protection is activated. —
1114 Selector out of service fault - Door zone.
Possible Causes:
• Leveling speed too fast.
• Defective magnet.
•Defective selector.
Possible Solution:
• RFL and cycle the inspection switch to reset.
1115 The car failed to run because the door held. —
1116 Ambient temperature is out of range (-10°C. to 70°C.)
• Controller too hot or cold as sensed by IOF Card’s tempera-
ture sensor.
1120
The left dynamic jack sensor did not activate when it should
have.
• Improper left dynamic sensor installation.
• A defective left dynamic sensor.
1121
The right dynamic jack sensor did not activate when it should
have.
• Improper left dynamic sensor installation.
• A defective left dynamic sensor.
1122
The car was already in slowdown when the dynamic jack
resynch sensors were activated.
Note: Dynamic sensors should activate 12 inches before the
slowdown point.·
• Improper left dynamic sensor installation.
• A defective left dynamic sensor.
• The slowdown distance is too long.
1123 Up Run stalled. • Z44 value exceeded.
1124 Car top inspection Node B CAN communication is offline. —
1129 SEL Node A/B data mismatch. —
1130 Car top inspection Nodes A/B Data mismatch.
•Noise.
•DPIA Card.
1133 SEL Node A reported a duplicate node. —
1134 SEL Node B reported a duplicate node. —
1135 Car top inspection Node A reported a duplicate node. • DPIA not configured.
1136 Car top inspection Node B reported a duplicate node. • DPIA not configured.
1141 SEL Node A data error. —
1142 SEL Node B data error. —
1143 Car top inspection Node A data error.
•DPIA Card.
• Car CAN issue.
•Noise.
1144 Car top inspection Node B data error.
•DPIA Card.
• Car CAN issue.
•Noise.
1150
Up Run stalled due to a command to Run Up, but no encoder
pulses were detected with Z44.
•Check the selector.
• Z44 too short.
• Car not moving.
1151 SEL Node A SPI Loop Error. —
1152 SEL Node A CAN communication is offline. —
1153 SEL Node B CAN communication is offline. —
1154 Car Top Inspection Node A CAN communication is offline.
•DPIA Card.
• Car CAN issue.
•Noise.
1155 DZ Node A CAN communication is offline. —
1156 DZ Node B CAN communication is offline. —
1157 DZ Node A/B data mismatch. —
1158 DZ Node A reported a duplicate node. —
1159 DZ Node B reported a duplicate node. —
1160 DZ Node A data error. —
Code Description (cont.) Possible Causes/Solutions (cont.)