ADJUSTMENT
Vertical Express Product Manual 2-41 88500 v.1.0
Adjustment Section Operational Adjustments
Save Parameters and Backup Job Software
1. Place the controller inspection switch in the INSP position.
2. Access the UIT.
3. Press UP or DOWN to scroll to the Startup Wizard.
4. Press ENTER to select the Startup Wizard, and then press UP.
5. Press UP until Write to Flash displays.
6. Press ENTER, and press ENTER again, and the UIT displays Save Job To USB.
7. Insert the USB flash drive for the job, and press ENTER. The CPU will
create a backup folder in the tke folder, and save the job software. This
process will take several minutes.
8. When the process is complete, press ENTER.
9. Press DOWN.
10. Place the controller inspection switch in the NORMAL position.
11. Return the car to service.