CAN Node Configuration via the Startup Wizard Service Information Section
©Vertical Express 5-22 Printed in USA November 2019
CAN Node Configuration via the Startup Wizard
The Startup Wizard will setup and configure all CAN nodes, execute a hoistway scan, and
save parameter changes.
CAN Nodes Before using the Startup Wizard, the door operator and safety system nodes must be
installed and completely wired to the cards (CNA, Selector, DPIA, CNs, etc.). When the cor-
rect termination scheme is used, CAN channels 2 (and 3 when required) should measure
60 ohms +/- 3 ohms, with power removed and all connections made.
Configure the CAN System
1. Access the UIT.
2. Access the Startup Wizard.
a. Press UP or DOWN until Block Select Startup Wizard displays, and then press
ENTER.
b. When Start Wizard? displays, press UP.
3. Issue the Teach Command.
a. When Teach Front CN? displays,
For Front Riser - press ENTER, and press ENTER again.
No Front Riser - press UP.
b. When Teach Rear CN? displays,
For Rear Riser - press ENTER, and press ENTER again.
No Rear Riser - press UP.
4. Configure the CNs.
a. When Config CN displays, press ENTER.
b. When Completed Config displays, press ENTER.
5. Skip Automatic Hoistway Scan. When Auto Hoistway Scan? displays, press UP.
6. Save the parameters.
a. When Write to Flash displays, press ENTER.
b. When Write Complete displays, press ESC.