EasyManua.ls Logo

Vertical Express ICON 32 - Door Setup and Final Adjustments

Vertical Express ICON 32
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Preliminary Setup for Automatic Operation Adjustment Section
©Vertical Express 2-26 Printed in USA April 2020
Hoistway Scan Through the Startup Wizard
(continued)
6. Press UP or DOWN to scroll to the Startup Wizard.
7. Press ENTER, and then press UP.
Reminder: Before starting a hoistway scan, the door operator limits (DCL, DOL) must be
correctly adjusted.
8. Repeatedly press UP until the UIT displays Auto Hoistway Scan.
9. Press ENTER to scan the hoistway, and the UIT displays Auto Hoistway Scan.
The Auto Hoistway Scan will automatically run the car at leveling speed to the bottom
directional limit, and then up to the top directional limit, scanning the hoistway tape to
learn the floor levels. If the hoistway scan was successful, the car should have leveled
down into the top terminal landing.
a. If the hoistway scan was not successful, verify and correct magnet placement and
orientation.
Leveling speed = 8-12 FPM.
Gate/Lock circuits are not opening up during the run.
Direction limits should not exceed 1
1
/
2
" from the terminal landing.
The appropriate NTS and LV I/Os must be active when on DL.
The proper polarity of each magnet must be used.
b. To view learned floor levels, scroll to Commands > Commands Common >FCP.
10. The UIT displays Write to Flash, and this function saves all settings and values to the
CPU’s card memory. Press ENTER to perform this operation.
11. When NEXT TEST? displays, press ENTER and the UIT displays Save Job to USB. This
action archives the job’s controller CPU files to a USB memory stick.
a. Install the manufacturing-provided USB flash drive included with the job.
b. Press ENTER to perform this operation, and the UIT displays Backing Software.
c. When the UIT displays Backup Complete, press ENTER and then press DOWN to
exit the Startup Wizard.
d. On the IOF Card, place the door disconnect switch in the OFF position.
Door Setup and Final Adjustments
See the appropriate door operator component manual.

Table of Contents