PRELIMINARY TESTING
Table 7. SmartDC Controller Board Inputs
Terminal
No�
Label/Input
Name
Wire Connecon Uses
15 Sensor 3 N.C. input. Connecon of a Monitored
External Entrapment sensor. Type
of sensor used is programmable in
Installer Menu (S3).
External entrapment sensors.
16 Free Exit Vehicle
Detector
N.O. input. Connecon for free exit
vehicle detector.
Vehicle detector, box type
connecons for free exit
loop.
17 Block Free Exit
vehicle detector
or Close Timer
N.O. input. Free Exit is only disabled if
Close Limit Switch is tripped.
If the gate is parally
opened, the Free Exit
detector will trigger the gate
to open fully. Input can be
converted in Installer Menu
to alternately disable Close
Timer.
18 Inside
Obstrucon
Vehicle Detector
N.O. input. Inside reversing loop. Vehicle detector, box type
connecons inside reversing
loop.
19 Outside
Obstrucon
Vehicle Detector
N.O. input. Outside reversing loop. Vehicle detector, box
type connecons outside
reversing loop.
20 Center Loop
(Shadow) Vehicle
Detector
N.O. input. Shadow funcon used
for swing gates or Reset Loop for
barrier arms only. However, User
Relay 20 can be used in combinaon
with a detector to perform an "arming
loop" or "annunciaon loop" funcon
because there is no associated
gate control logic in a slide gate.
Vehicle detector, box type
connecons. Shadow
funcon for swing gates,
reset funcon for barrier arm
gates.

Table of Contents