Alpha/Delta (Kinetic Operator) Installation and Maintenance Manual Revision 1 - MAY 2023
123
CONNECTING HY5B VEHICLE DETECTORS
Table 8. Vehicle Detector - Congurable Funcons
Display Meaning Installer Menu Seng Opons
(Bold - Default)
OR 1 Outside Obstrucon loop detector funcon 0= Pause closing only
1= Enable reverse to open
IR 1 Inside Obstrucon loop detector funcon 0= Pause closing only
1= Enable reverse to open
DL 1 Vehicle detector logic 1 = Standard (Close Timer does not begin
counng unl all loops have cleared.)
2 = Quick close (Close Timer can count to
zero, even while loops are acve, so the
gate will close as soon as the loops are
clear.)
3 = Forced me out (Close Timer is forced
to zero when both the OOLD & IOLD are
tripped simultaneously. Addionally, all
other close inputs are memorized and the
gate closes immediately when all open
commands and vehicle detector inputs are
clear.)
4 = Full An-tailgate (In addion to the
funcons of 3, the gate stops during the
opening cycle when both OOLD & IOLD are
tripped simultaneously. When the OOLD
and IOLD loops are cleared, the gate closes
immediately.)
For addional informaon, refer to “Vehicle
Detector Conguraon and Quick Close
Mode Selecon” on page 126.