Action Yes No
Step 7
Check if the distance between the
repeating defects is equal to any
of the following:
• 62.5mm (2.46in.)
• 79.8mm (3.14in.)
Does the distance between the
repeating defects match any of
the measurements?
Go to step 8. Contact the next level of support.
Step 8
Replace the fuser. See Fuser
removal.
Does the problem remain?
Contact the next level of support. The problem is solved.