3-74 Phaser 6121MFP Service Manual
Error Messages and Codes
004E LVPS Fan Failure
Possible causes:
• The Power Supply Cooling Fan Motor does not rotate evenly even after the 
lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time 
while the Power Supply Cooling Fan Motor is being rotated.
Initial Actions
Power down and reboot the printer.
Procedure 
Troubleshooting Reference Table
Applicable Parts Wiring and Plug/Jack References
■ Power Supply Cooling Fan Motor, 
PL12.0.11
■ Engine Control Board, PL13.0.20
■ Power Supply, PL13.0.17
■ Board Locations (page 2-10)
■ Motors, Fans, and Solenoids 
(page 2-12)
■ Map 1 - Engine Control Board 
Plug/Jack Locator (page 10-5)
■ Engine Control Board Wiring 
(page 10-14)
Troubleshooting Procedure Table
Step Action and Questions Yes No
1 Check the High Voltage Board 
connectors CN1 and CN2, and the 
Engine Control Board connector P/J17.
Are the connectors seated properly?
Go to step 2. Reseat the 
connector(s). If 
the problem 
persists, go to 
step 2.
2 Check the Power Supply Cooling Fan 
Motor control signals at CN2. 
Are the signals operating correctly?
Replace the 
motor 
(page 8-95). If 
the problem 
persists, go to 
step 3.
Go to step 3.
3 Check the Power Supply Cooling Fan 
Motor control signals at PJ17 on the 
Engine Control Board.
Are the control signals operating 
correctly?
Replace the 
High Voltage 
Board 
(page 8-57). If 
the problem 
persists, go to 
step 4.