EasyManuals Logo

YASKAWA P1000 Technical Manual

YASKAWA P1000
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Connecting a Noise Filter ................................................................................................................ 387
Installing Input Fuses ...................................................................................................................... 388
Attachment for External Heatsink Mounting (IP00 Enclosure) ........................................................ 390
Installing a Motor Thermal Overload (oL) Relay on the Drive Output ............................................. 390
A. SPECIFICATIONS ................................................................................................ 393
A.1 Power Ratings ...................................................................................................................394
Three-Phase 200 V Class Drive Models 2A0004 to 2A0030 .......................................................... 394
Three-Phase 200 V Class Drive Models 2A0040 to 2A0211 .......................................................... 395
Three-Phase 200 V Class Drive Models 2A0250 to 2A0415 .......................................................... 396
Three-Phase 400 V Class Drive Models 4A0002 to 4A0031 .......................................................... 397
Three-Phase 400 V Class Drive Models 4A0038 to 4A0165 .......................................................... 398
Three-Phase 400 V Class Drive Models 4A0208 to 4A1200 .......................................................... 399
Three-Phase 600 V Class Drive Models 5A0003 to 5A0032 .......................................................... 400
Three-Phase 600 V Class Drive Models 5A0041 to 5A0099 .......................................................... 401
Three-Phase 600 V Class Drive Models 5A0125 to 5A0242 .......................................................... 402
A.2 Drive Specifications ..........................................................................................................403
A.3 Drive Watt Loss Data ........................................................................................................405
A.4 Drive Derating Data ...........................................................................................................407
Single-Phase Derating .................................................................................................................... 407
Rated Current Depending on Carrier Frequency ............................................................................ 426
Temperature Derating ..................................................................................................................... 428
Altitude Derating.............................................................................................................................. 429
B. PARAMETER LIST............................................................................................... 431
B.1 Understanding Parameter Descriptions..........................................................................432
Parameter Icons .............................................................................................................................. 432
Parameter Groups........................................................................................................................... 432
B.2 A: Initialization Parameters ..............................................................................................433
A1: Initialization ............................................................................................................................... 433
A2: User Parameters....................................................................................................................... 433
B.3 b: Application.....................................................................................................................434
b1: Operation Mode Selection......................................................................................................... 434
b2: DC Injection Braking and Short Circuit Braking......................................................................... 434
b3: Speed Search............................................................................................................................ 435
b4: Timer Function .......................................................................................................................... 436
b5: PID Control................................................................................................................................ 436
b6: Dwell Function........................................................................................................................... 439
b8: Energy Saving ........................................................................................................................... 440
B.4 C: Tuning............................................................................................................................441
C1: Acceleration and Deceleration Times ....................................................................................... 441
C2: S-Curve Characteristics............................................................................................................ 441
C3: Slip Compensation.................................................................................................................... 442
C4: Torque Compensation .............................................................................................................. 442
C6: Carrier Frequency..................................................................................................................... 442
B.5 d: References.....................................................................................................................443
d1: Frequency Reference................................................................................................................ 443
d2: Frequency Upper/Lower Limits ................................................................................................. 444
d3: Jump Frequency........................................................................................................................ 444
d4: Frequency Reference Hold and Up/Down 2 Function............................................................... 444
Table of Contents
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
11

Table of Contents

Other manuals for YASKAWA P1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA P1000 and is the answer not in the manual?

YASKAWA P1000 Specifications

General IconGeneral
Operating Temperature-10°C to +50°C (14°F to 122°F)
Cooling MethodFan Cooled
Output Voltage0-Input Voltage
Output Frequency0-400 Hz
Frequency Range0.1-400 Hz
Power Rating0.4 kW to 630 kW
Control MethodV/f Control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit, Ground Fault
Protection FeaturesElectronic Thermal Overload Protection
CommunicationModbus RTU
Communication InterfaceRS-485
Humidity5% to 95% (non-condensing)
AltitudeUp to 1000m (3280ft) without derating
Enclosure RatingIP20

Related product manuals