EasyManuals Logo

YASKAWA P1000 Technical Manual

YASKAWA P1000
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #579 background imageLoading...
Page #579 background image
Index
................................................................................83
+
+1 ..............................................................................83
+2 ..............................................................................83
+3 ..............................................................................83
+V..............................................................................96
Numerics
24 V Power Supply ........................................................376
2-Wire Initialization .......................................................143
3-Wire Initialization .......................................................143
3-Wire Sequence...........................................................206
5th Most Recent Fault.....................................................482
A
A/D Conversion Error.....................................................296
A1..............................................................................96
A1-01........................................................................137
A1-03........................................................................137
A1-04, A1-05: Password and Password Setting .......................143
A2..............................................................................96
A2-01........................................................................137
A2-32........................................................................137
A2-33........................................................................137
A3..............................................................................96
AC .............................................................................96
Accel/Decel Rate Calculation Gain .....................................251
Accel/Decel Time....................................................290, 403
Accel/Decel Time Setting Units .........................................178
Accel/Decel Time Switching Frequency ...............................177
Acceleration Error .........................................................324
Acceleration Time .........................................................177
Access Level Selection..............................................137, 142
AC Reactor .................................................................376
Additional DC Bus Capacitors...........................................252
Adjusted Slip Calculation Error .........................................322
AEr...........................................................................311
Alarm Outputs for Maintenance Monitors .............................344
Alarm Register 007FH Contents.........................................535
Alarms and Errors ............................................................3
Allowable Frequency Fluctuation ...............397, 398, 400, 401, 402
Allowable Voltage Fluctuation ..................397, 398, 400, 401, 402
ALM LED Light ...........................................................109
Altitude........................................................................48
AM.............................................................................96
Ambient Temperature .......................................................48
Ambient Temperature and Installation Method Derating
............428
Ambient Temperature Setting................................260, 428, 467
Analog Filter Time Constant .............................................290
Analog Frequency Reference Fluctuation Limit.......................189
Analog Frequency Reference Sample/Hold............................210
Analog Input Filter Time Constant......................................227
Analog Inputs / Pulse Train Input .........................................96
Analog Input Terminal Enable Selection ...............................227
Analog Monitor Card Settings ...........................................198
AO-A3.......................................................................376
AO-A3 Settings ............................................................198
Application Selection ........................................................3
Attachment for External Heatsink .................................376, 390
Automatic Reduction for Stall Prevention during Run ...............251
Automatic Reduction Selection for Stall Prevention during Run ...465
Auto Restart Fault Output Operation Selection........................255
Auto Restart Operation Selection........................................466
Auto-Tuning.......................................................3, 129, 132
Auto-Tuning Codes........................................................322
Auto-Tuning Errors........................................................294
Auto-Tuning Fault Codes.................................................130
Auto-Tuning Fault Detection.............................................322
Auto-Tuning Fault Solutions.............................................322
Auto-Tuning for Induction Motors ......................................129
Auto-Tuning Input Data ............................................129, 130
Auto-Tuning Interruption and Fault Codes.............................130
Auto-Tuning Mode Selection ......................................132, 478
B
B1 ..............................................................................83
B2 ..............................................................................83
b6-01 through b6-04.......................................................290
Backing Up Parameter Values ...........................................137
Baseblock ...................................................................311
Base Frequency ............................................................194
Base Voltage ...............................................................195
Basic Auto-Tuning Preparations.........................................129
bAT ..........................................................................295
bb.............................................................................311
Bi-Directional Speed Search Selection .................................158
boL.....................................................................295, 311
Braking circuit protective cover ...........................................94
Braking Resistor .....................................................376, 382
Braking Resistor Fault ....................................................306
Braking Resistor Overheat................................................306
Braking Resistor Overheat Protection ..................................404
Braking Resistor Overload Protection ..................................383
YASKAWA
SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
579

Table of Contents

Other manuals for YASKAWA P1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA P1000 and is the answer not in the manual?

YASKAWA P1000 Specifications

General IconGeneral
Operating Temperature-10°C to +50°C (14°F to 122°F)
Cooling MethodFan Cooled
Output Voltage0-Input Voltage
Output Frequency0-400 Hz
Frequency Range0.1-400 Hz
Power Rating0.4 kW to 630 kW
Control MethodV/f Control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit, Ground Fault
Protection FeaturesElectronic Thermal Overload Protection
CommunicationModbus RTU
Communication InterfaceRS-485
Humidity5% to 95% (non-condensing)
AltitudeUp to 1000m (3280ft) without derating
Enclosure RatingIP20

Related product manuals