EasyManuals Logo

YASKAWA P1000 Technical Manual

YASKAWA P1000
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
5.2 b: Application.....................................................................................................................147
b1: Operation Mode Selection......................................................................................................... 147
b2: DC Injection Braking and Short Circuit Braking......................................................................... 152
b3: Speed Search............................................................................................................................ 153
b4: Timer Function .......................................................................................................................... 160
b5: PID Control................................................................................................................................ 160
EZ Sleep/Wake-up Function ........................................................................................................... 168
b6: Dwell Function........................................................................................................................... 174
b8: Energy Saving ........................................................................................................................... 175
5.3 C: Tuning............................................................................................................................177
C1: Acceleration and Deceleration Times ....................................................................................... 177
C2: S-Curve Characteristics............................................................................................................ 178
C3: Slip Compensation.................................................................................................................... 179
C4: Torque Compensation .............................................................................................................. 180
C6: Carrier Frequency..................................................................................................................... 180
5.4 d: Reference Settings .......................................................................................................182
d1: Frequency Reference................................................................................................................ 182
d2: Frequency Upper/Lower Limits ................................................................................................. 184
d3: Jump Frequency........................................................................................................................ 185
d4: Frequency Reference Hold and Up/Down 2 Function............................................................... 186
d6: Field Weakening and Field Forcing........................................................................................... 190
5.5 E: Motor Parameters .........................................................................................................191
E1: V/f Pattern for Motor 1............................................................................................................... 191
E2: Motor 1 Parameters .................................................................................................................. 195
5.6 F: Option Settings .............................................................................................................198
F4: Analog Monitor Card Settings ................................................................................................... 198
F6 and F7: Communication Option Card......................................................................................... 199
CC-Link Parameters........................................................................................................................ 200
MECHATROLINK Parameters ........................................................................................................ 201
PROFIBUS-DP Parameters ............................................................................................................ 202
CANopen Parameters ..................................................................................................................... 202
DeviceNet Parameters .................................................................................................................... 203
5.7 H: Terminal Functions.......................................................................................................205
H1: Multi-Function Digital Inputs ..................................................................................................... 205
H2: Multi-Function Digital Outputs................................................................................................... 215
H3: Multi-Function Analog Inputs .................................................................................................... 225
H4: Multi-Function Analog Outputs ................................................................................................. 230
H5: MEMOBUS/Modbus Serial Communication ............................................................................. 232
H6: Pulse Train Input....................................................................................................................... 232
5.8 L: Protection Functions ....................................................................................................234
L1: Motor Protection ........................................................................................................................ 234
L2: Momentary Power Loss Ride-Thru............................................................................................ 240
L3: Stall Prevention ......................................................................................................................... 247
L4: Speed Detection........................................................................................................................ 253
L5: Fault Restart.............................................................................................................................. 254
L6: Torque Detection....................................................................................................................... 255
L8: Drive Protection......................................................................................................................... 257
5.9 n: Special Adjustments.....................................................................................................264
n1: Hunting Prevention.................................................................................................................... 264
n3: High Slip Braking (HSB) and Overexcitation Braking................................................................ 264
Table of Contents
8
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual

Table of Contents

Other manuals for YASKAWA P1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA P1000 and is the answer not in the manual?

YASKAWA P1000 Specifications

General IconGeneral
Operating Temperature-10°C to +50°C (14°F to 122°F)
Cooling MethodFan Cooled
Output Voltage0-Input Voltage
Output Frequency0-400 Hz
Frequency Range0.1-400 Hz
Power Rating0.4 kW to 630 kW
Control MethodV/f Control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Short Circuit, Ground Fault
Protection FeaturesElectronic Thermal Overload Protection
CommunicationModbus RTU
Communication InterfaceRS-485
Humidity5% to 95% (non-condensing)
AltitudeUp to 1000m (3280ft) without derating
Enclosure RatingIP20

Related product manuals