Installation
180
Aastra 470 ab R3.0
syd-0337/1.5 – R3.0 – 05.2013
Tab. 79 Connections on the Aastra DECT radio units
If an SB-8 / SB-8ANT is operated on two DSI interfaces, it is recommended always to
use two neighbouring ports.
Aastra Intelligent Net:
As the DECT systems of the individual nodes in an AIN do not run syn-
chronously, the two DSI interfaces of an SB-8 / SB-8ANT must always be
connected to the same node.
Tab. 80 Operating state display on Aastra DECT radio units
For further display variants, see "Operating state of the Aastra DECT radio units",
page 270
RJ12 sockets Pin Socket 1: DSI interface Socket 2: Power supply
SB-4+ SB-8 / SB-8ANT SB-4+ / SB-8 / SB-8ANT
1 Local power supply – Local power supply – Local power supply –
2 b2
3b1 b1
4a1 a1
5 a2
6 Local power supply + Local power supply + Local power supply +
LED flashing (two LEDs on the SB-8) Information
green Operating state
red / green Startup procedure running
orange Transmission of DECT sequences
red Fault
not flashing and not lit LED switched off or radio unit defective or not in operation