Operation and Maintenance
251
Aastra 470 ab R3.0
syd-0337/1.5 – R3.0 – 05.2013
IP address changed: Re-gen-
erate TLS certificate
The IP address of the communication server has
changed. The TLS certificates have to be re-
generated. For terminals downcircuit from a
NAT without ALG the public NAT gateway
address has to be configured.
Date, time
IP phone: Connection lost An IP system phone is no longer connected to
the communication server.
User number, terminal ID, date,
time
IP phone: Connection re-
established
An IP system phone has re-established the con-
nection to the communication server.
User number, terminal ID, date,
time
IP system phone licence is
now available
A sufficient number of licences is now available
again for Aastra 5360ip/5361ip/5370ip/5380ip.
Date, time
LCR on alternative network
provider
Automatic switch from primary network pro-
vider to secondary network provider using LCR
function
Provider ID, date, time
Licence for mobile phone
available
A sufficient number of licences is now available
again for integrated mobile phones.
Date, time
Licence for PMS interface
available
The Hospitality PMS Interface or a sufficient
number of Hospitality PMS Rooms licences ara
now available.
Date, time
Licence invalid; restricted
operating mode 4 hours after
restart
The system software loaded requires a software
release licence. Without this licence the system
software’s functionality is severely restricted 4
hours after the restart.
Date, time
Licences for offline operations
expired
The maximum duration of two hours for the
temporary licence activation has expired.
Date, time
Local supply error on the radio
unit
Local power supply of a SB-4+ / SB-8 / SB-8ANT
radio unit failed or unavailable
Card number, port number,
date, time
Local supply on radio unit
available
Local power supply of a SB-4+ / SB-8 / SB-8ANT
is now again available
Card number, port number,
date, time
Login error • Card not fitted
• Card not logged on
• Card defective
Card number, date, time
Mains voltage failure Event message once mains power is restored
• Mains power has failed more frequently than
entered in the trigger table
Date, time
Malfunction A hardware or software error has occurred. The
error ID can help Support to pinpoint the possi-
ble cause of the error.
Error ID, date, time
Monitor Event Monitor Event Monitor Type, Date, Time
No DECT-DSP channels avail-
able
DECT channels on DSP-0x overloaded Date, time
No DTMF receiver available
for integrated mobile phones
A permanent DTMF receiver (for detection suf-
fix dialling function codes) could not be
assigned to an integrated mobile phone with
enhanced functionality.
BCS Ref., date, time
Event / error message Trigger condition Details