Operation and Maintenance
252
Aastra 470 ab R3.0
syd-0337/1.5 – R3.0 – 05.2013
No free IP system phone
licences
An Aastra 5360ip/5361ip/5370ip/5380ip was
unable to register because there are too few IP
system phone licences.
Date, time
No response from network No answer to Call Setup on BRI-T/PRI interface Port number of the exchange
line circuit, date, time
Node:
Connection lost
A node is not connected to the Master for a cer-
tain amount of time (configurable).
Node number, date, time
Node:
Connection re-established
A node is reconnected with the Master for a cer-
tain amount of time (configurable) after an
interruption.
Node number, date, time
Not enough mobile phone
licences
The connection setup with an integrated
mobile phone has failed because the number
of configured mobile phones is greater than
the number of licences available. All the inte-
grated mobile phones remain blocked until a
sufficient number of licences are available.
Number of licences, number of
configured mobile phones,
date, time
NTP: Time synchronisation
failed
Time synchronization via the NTP server (NTP =
Network Time Protocol) has failed.
Date, time
NTP: Time synchronisation
reestablished
Time synchronization via the NTP server (NTP =
Network Time Protocol) has been restored.
Date, time
Outgoing call rejected Call rejected by the network
• On any line: error code 34
• On required line group:
error code 44
Port number of the exchange
line circuit, cause, date, time
Overheat The temperature inside the communication
server is too high. Appropriate measures must
be taken immediately to improve heat dissipa-
tion. Measures are automatically adopted,
depending on where the overheating occurs:
FXO and FXS interface card:
• the ports are deactivated in groups of 4 ports.
• Once they have cooled down below a defined
card-specific value, the ports are automati-
cally reactivated group by group.
Application card CPU2:
• The card will be completely deactivated.
Once it has cooled down below a defined
value, the card is automatically reactivated.
Internal power suply unit PSU2U or call man-
ager card CPU1:
• the communication server will be shut down
completely.
Notes:
• To prevent the system from overheating, no
more than 30% of the FXS ports should be
active simultaneously per 32FXS card and no
more than 50 FXS ports per system.
• PRI, BRI and DSI cards do not have tempera-
ture sensors and are therefore never deacti-
vated due to overheating.
Card number, temperature,
date, time
Event / error message Trigger condition Details