Operation and Maintenance
253
Aastra 470 ab R3.0
syd-0337/1.5 – R3.0 – 05.2013
Overload detected at USB
port (CPU2)
A (current) overload was detected at one of the
USB interfaces on the applications card (CPU2).
Note: The maximum current input at the USB
interfaces varies (see Tab. 27).
Date, time
Port out of service A port previously in operation has stopped
functioning.
Number of the slot, relevant
port number, date, time
QSIG licence limit reached Maximum number of licensed outgoing con-
nections with QSIG protocol exceeded
Route number, user number,
date, time
Radio unit port active The radio unit is responding again Card number, port number,
date, time
Remote maintenance disa-
bled
Remote maintenance has been deactivated Date, time
Remote maintenance is acti-
vated
The remote maintenance has been activated
(The report is output unfiltered on local desti-
nations).
Date, time
Reset card A reset was carried out for one card Number of the expansion slot,
date, time
Satellites missing after super-
vision time
After an AIN update (Master and all satellites)
some satellites no longer have a connection to
the Master.
Total satellites missing, Satel-
lites rolled back, Date, Time
Send e-mail failed The system was unable to send an e-mail
because an error occurred.
Meaning of the parameter values in Tab. 104
Cause/action, e-mail client,
additional information, date,
time
SIMPLE/MSRP back within the
licence limit
There are now enough licences available for
using the MSRP and/or SIMPLE protocol for
users.
Date, time
SIP account available The SIP account cannot register with the SIP
provider for a certain reason (0: Provider unob-
tainable / 1: no permission). The event is trig-
gered only if the parameter Registration
required is configured to Yes .
Provider, account, date, time
SIP account available The SIP account has successfully registered
with the SIP provider.
Provider, account, date, time
SMS gateway reachable External SMS gateway again reachable Date, time
SMS gateway unreachable External SMS gateway unobtainable by net-
work provider or incorrectly configured
Date, time
Software upgrade IP system
phone failed
The software update of an Aastra 5360ip/
5361ip/5370ip/5380ip has failed for the stated
reason.
User number, terminal ID, rea-
son, date, time
Software upgrade IP system
phone successful
The software update of an Aastra 5360ip/
5361ip/5370ip/5380ip has now been success-
fully completed after unsuccessful attempt(s).
User number, terminal ID, date,
time
Event / error message Trigger condition Details

Table of Contents

Other manuals for Aastra 470

Related product manuals