314 Chapter5
Programming
Data Transfer to Computer
Example 10 uses the I-block format to separate the # and I characters
from the trace data.
EXAMPLE 10
10 INTEGER Tra_binary(1:601)
20 DIM Header$[2]
30 OUTPUT 718;"IP;CF 300MHZ;SP 20MHZ;SNGLS;TS;"
40 CALL Get_settings(Fa,Fb,Rl,Rb,Vb,St,Lg,Aunits$)
50 OUTPUT 718;"TDF I;TRA?;"
60 ENTER 718 USING "#,2A,601(W)";Header$,Tra_binary(*)
70 END
Like the examples for the A-block format, you store format information
in a string (Header$) and store the desired trace data in an integer
array (Tra_binary).
Returning the trace data to the analyzer requires an important
instruction. The "I" in the term I-block refers to the ability of the
spectrum analyzer to accept data of "indefinite" length when using
I-block format. Even though the analyzer uses only 601 points of trace
data, the I-block format lets you send any number of data points. The
spectrum analyzer will continue to accept data until an
end-of-instruction (EOI) signal is sent to it. HP 9000 Series 200/300
BASIC allows you to send an EOI with the last data byte using the
END command. Refer to Example 11.
E
XAMPLE 11
10 INTEGER Tra_binary(1:601)
20 DIM Header$[2]
30 OUTPUT 718;"IP;CF 300MHZ;SP 20MHZ;SNGLS;TS;"
40 CALL Get_settings(Fa,Fb,Rl,Rb,Vb,St,Lg,Aunits$)
50 OUTPUT 718;"TDF I;TRA?;"
60 ENTER 718 USING "#,2A,601(W)";Header$,Tra_binary(*)
70 PRINT "PRESS CONTINUE TO RETURN DATA TO THE ANALYZER"
80 PAUSE
90 OUTPUT 718;"IP;TS;VIEW TRA;"
100 CALL Setup_analyzer(Fa,Fb,Rl,Rb,Vb,St,Lg,Aunits$)
110 OUTPUT 718;"TDF I;"
120 OUTPUT 718 USING "#,K,601(W)";"TRA#I",Tra_binary(*) END
130 END
By now most of this program should look familiar. Line 120 requires
some explanation, however. The END statement appearing after the
array Tra_binary sends (to the spectrum analyzer) the last data byte
stored in the array, with the GPIB EOI line set "true," as required by
I-block format.
See Table 5-2 on page 315 for an example of how data is sent to the
computer using the TDF I format.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8563E and is the answer not in the manual?

Agilent Technologies 8563E Specifications

General IconGeneral
BrandAgilent Technologies
Model8563E
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals