Chapter 7 569
Language Reference
RB Resolution Bandwidth
RB Resolution Bandwidth
Syntax
Figure 7-217 RB Syntax
Description
The RB command sets the resolution bandwidth. This is normally a
coupled function that is selected by the span setting according to the
ratio selected by the RBR command. If no ratio is selected, a default
ratio (0.011) is used. The bandwidth, which ranges from 1 Hz to 2 MHz
(or 10 Hz to 2 MHz for Option 103), can also be selected manually.