Virtual Leased Line Services
7210 SAS M Services Guide Page 161
If a spoke SDP in endpoint “Y”, including the ICB spoke SDP, received T-LDP SAP down status
bits, and/or received T-LDP SDP-binding down status bits, and/or received status bits of
pseudowire not forwarding, the node saves this status and takes no further action. The saved status
is used for selecting the active transmit endpoint object.
If all objects in endpoint “Y”, except the ICB spoke SDP, transition locally to down state, and/or
received T-LDP SAP down status bits, and/or received T-LDP SDP-binding down status bits, and/
or received status bits of pseudowire not forwarding, the node must send status bits of SDP-
binding down over the “X” endpoint ICB spoke SDP only.
If all objects in endpoint “Y” transition locally to down state, and/or received T-LDP SAP down
status bits, and/or received T-LDP SDP-binding down status bits, and/or received status bits of
pseudowire not forwarding, the node must send status bits of SDP-binding down over the “X”
endpoint ICB spoke SDP, and must send a SAP down notification on the “X” endpoint SAP by the
SAP specific OAM signal if applicable. An Ethernet SAP does not support signaling status
notifications.

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS M and is the answer not in the manual?

Alcatel-Lucent 7210 SAS M Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS M
CategorySwitch
LanguageEnglish

Related product manuals