VLL Service Configuration Commands
Page 240 7210 SAS M Services Guide
For unstructuredE1, unstructuredT1, unstructuredE3 and unstructuredT3, the payload size must
be a multiple of 32 bytes.
Configuring the payload size and jitter buffer to values that result in less than 2 packet buffers or
greater than 32 packet buffer is not allowed.
Setting the payload size to 0 sets it back to the default value.
Values 0, 64, 1472
report-alarm
Syntax [no] report-alarm [stray] [malformed] [pktloss] [overrun] [underrun] [rpktloss] [rfault]
[rrdi]
Context config>service>cpipe>sap>cem
Description This command indicates the type of CEM SAP alarm.
The no form of the command removes the parameter from the configuration.
Parameters stray — Reports the reception of packets not destined for this CES circuit.
malformed — Reports the reception of packet not properly formatted as CES packets.
pktloss — Reports the lack of reception of CES packets.
overrun — Reports reports the reception of too many CES packets resulting in a overrun of the
receive jitter buffer.
underrun — Reportsreports the reception of too few CES packets resulting in a overrun of the
receive jitter buffer.
rpktloss — Reports hat the remote peer is currently in packet loss status.
rfault — Reports that the remote TDM interface is currently not in service.
rrdi — Reports that the remote TDM interface is currently in RDI status.
rtp-header
Syntax [no] rtp-header
Context config>service>cpipe>sap>cem
Description This command specifies whether an RTP header is used when packets are transmitted to the packet
service network (PSN) by the CEM SAP.
Default no rtp-header
Endpoint Type Timeslots Default Payload Size (in bytes)
unstructuredE1 n/a 256
unstructuredT1 n/a 192