GreenDrill control terminal 5.2
GreenDrill BAH0054-9 11.17
93
7.18.4 Signal sources
The control terminal shows the forward speed [km/h] and adjusts the seeding shaft speed according to
the changing forward speed. The seed rate [kg/ha] remains unchanged even at varying forward
speeds. If it is set correctly, speed differences of 50 % are adjusted up or down.
When the implement is raised, e.g., when turning at the end of the field, the seeding shaft automatical-
ly stops rotating. When the implement is lowered to the working position after turning, the seeding
shaft starts rotating again.
For displaying, control terminal 5.2 needs the following 3 signals:
Actual forward speed [km/h]
The implement is in working position (e.g. lifting gear signal from the tractor)
The implement is in transport position (e.g. lifting gear signal from the tractor).
The signal source must be entered in the programming menu (see section "Signal sources", page
101).
7.18.4.1 Tractor signal socket (7-pin)
The signal cable (1) transmits the 3 signals from
the 7-pin tractor signal socket to the control ter-
minal.
Connect the signal cable to the 12-pin signal