GreenDrill control terminal 5.2
72
GreenDrill BAH0054-9 11.17
7.6.2 Calibration [grains/m
2
]
1. Make all of the entries shown in section 7.6, page 69.
2. Select the display with the
buttons.
3. Confirm the selection with the
button.
4. Enter the desired spread rate (e.g. 100 grains/m
2
)
with the
buttons.
5. Confirm the entry with the
button.
6. Select the display with the buttons.
7. Confirm the selection with the
button.
8. Enter the 1000-grain weight with the
buttons
(e.g. 30 g).
9. Confirm the entry with the
button.
10. Select the display with the buttons.
11. Confirm the selection with the
button.
12. Enter the germination capacity of the seed
with the
buttons (e.g. 95 %).
13. Confirm the entry with the
button.