GreenDrill control terminal 5.2
70
GreenDrill BAH0054-9 11.17
7.6.1 Calibration [kg/ha]
1. Make all of the entries shown in section 7.6, page 69.
2. Select the display with the
buttons.
3. Confirm the selection with the
button.
4. Enter the desired spread rate
with the
buttons (e.g. 103.5 kg/ha).
5. Confirm the entry with the
button.
6. Select the display with the buttons.
7. Confirm the selection with the
button.
8. Enter the desired duration
1)2)
for the calibration test with
the
buttons (e.g. 0.5 min).
9. Confirm the entry with the
button.
1)
Calibrate for 0.5 minutes
for seeds, e.g., wheat, barley, peas and large spread rates
Calibrate for 1.0 minute
for all seeds (standard)
Calibrate for 2.0 minutes
for fine seeds, e.g., rapeseed and phacelia.
2)
The "Calibration duration" menu item does not appear when
the GreenDrill has a calibration button (see section 7.6.3, page 74) and
the menu item "Calibration button available" (see section 7.20.10, page 104) is answered
with "YES".