7-20
129390199 Operator Manual Cycle and Control Value Programming
Using automatic utility control, the sterilizer can be set to control the
following:
• Daily Restart time
• Daily Shutoff time
NOTE: Restart and Shutoff times are set up separately for each day
of the week.
1. Press the Day Of The Week button to select the day to set up for
utility control.
•The Day Of The Week button sequentially displays the days
of the week each time it is pressed.
• Press the button repeatedly until reaching the day of the
week to be set up.
• Separate Restart and Shutoff times are set up for each day of
the week.
• Any previously set Restart and Shutoff times are displayed
on the Restart Time and Shutoff Time buttons as each day
is displayed.
2. Once the day of the week has been selected, press Restart
Time button to set up the automatic Restart time.
3. Enter the correct Restart time value using the keypad. The
Restart time value must be entered as a valid time of the day in
24-hour format (e.g., 4:00 pm = 16:00).
• For utilities to be on all day, enter "00:00" in both Restart
Time and Shutoff Time.
• For utilities to be off all day, enter "24:00" in Restart Time
and "00:00" in Shutoff Time.