A-3 LTE Messages
A-2 PN: 10580-00234 Rev. T 3GPP MG
A-3 LTE Messages
1. Sync signal not found
When the firmware does not find a synchronization signal (P-SS and S-SS), this
message is displayed. Measurement results are cleared (‘--’ is seen in the result area for
all modulation and Scanner results. Channel Power will continue to be displayed).
2. Demodulation Error
When a wrong cell ID is entered after setting Sync Type to RS, this message is
displayed. All Measurement results are cleared.
A-4 TD-LTE Messages
1. Sync signal not found
When the firmware does not find a synchronization signal (P-SS and S-SS), this
message is displayed. Measurement results are cleared (‘--’ is seen in the result area for
all modulation and Scanner results. Channel Power will continue to be displayed).
2. No Trigger found
When Trigger is set to ‘External’ and no external trigger is found, this message is
displayed. Results that depend on the trigger are cleared (‘--’ is seen in the result area)