STwrench User Guide Working with Power Focus
9836 4134 01 Edition 2.9 229 (326)
torque whose value is greater than the P119 value is applied, then an
event "loosening" is sent to the PF.
- When the operator has already started the tightening, and a
negative torque whose value is greater than the P119 value is
applied, then an event "loosening" is sent to the PF; the generated
result is forced to be NOK.
Set this parameter to zero to disable this function.
Function not available with STwrench
Check already tightened angle
P131 Step 1 speed
P133 Loosening speed
These parameters are not used by the STwrench. However, they
must be set in a consistent way in order not to produce errors. Set
them to any value that does not give an error.
P151 Batch size
Batch size
P240 Max coherent NOK result
Max coherent NOK result
This parameter must be always set to %.
Do not set it as RPM.
When the STwrench is working in Power Focus mode, this