Administrator's Manual 3. Manual Configuration of a Single IP Phone
Version 3.4.4 59 400HD IP Phones Series - Teams Compatible
Parameter Description
voip/regional_settings/call_progress_tones/
%d/cadence
Defines the cadence type of the tone.
[0] - Continuous signal
[1] - Cadence signal
[2]
- Burst signal
voip/regional_settings/call_progress_tones/
%d/frequency_a
Defines the low frequency (in Hz) of the tone.
Range: 300 - 1980 Hz, in steps of 1 Hz.
Unused frequencies must be set to zero.
voip/regional_settings/call_progress_tones/
%d/frequency_b
Defines the high frequency (in Hz) of the tone.
Range: 300 - 3000 Hz, in steps of 1 Hz.
Unused frequencies must be set to zero.
voip/regional_settings/call_progress_tones/
%d/frequency_a_level
Output level of the low frequency tone (in -dBm) in Call
Progress generation. Range: 0 - 63, where 63 is mute.
voip/regional_settings/call_progress_tones/
%d/frequency_b_level
Output level of the low frequency tone (in -dBm) in Call
Progress generation. Range: 0 - 63, where 63 is mute.
voip/regional_settings/call_progress_tones/
%d/tone_on_0
tone_on_0 to tone_on_3.
If the signal is Cadence or Burst, then this value
represents the on duration. If a Continuous tone, then
this value represents the minimum detection time. In
units of 10 msec. Range: 0 - 10000.
voip/regional_settings/call_progress_tones/
%d/tone_off_0
tone_off_0 to tone_on_3.
If the signal is Cadence, then this value represents the
off duration, in units of 10 msec. If not used, then set it
to zero. If the signal is Burst, only tone_off 0 is relevant.
It represents the off time that is required from the end of
the signal to the detection time. Range: 0 - 10000.