User's Manual 182 Document #: LTRT-65422
MP-11x & MP-124
Parameter Description
value.
Web/EMS: Is Proxy Hot-
Swap
[ProxySet_IsProxyHotS
wap]
Enables the Proxy Hot-Swap redundancy mode.
[0] No (default)
[1] Yes
If Proxy Hot-Swap is enabled, the SIP INVITE/REGISTER message is
initially sent to the first Proxy/Registrar server. If there is no response
from the first Proxy/Registrar server after a specific number of
retransmissions (configured by the parameter HotSwapRtx), the message
is resent to the next redundant Proxy/Registrar server.
Web/EMS: Redundancy
Mode
[ProxySet_ProxyRedun
dancyMode]
Determines whether the device switches back to the primary Proxy after
using a redundant Proxy.
[-1] Not configured = (Default) The global parameter,
ProxyRedundancyMode applies.
[0] Parking = The device continues operating with a redundant (now
active) Proxy until the next failure, after which it operates with the next
redundant Proxy.
[1] Homing = The device always attempts to operate with the primary
Proxy server (i.e., switches back to the primary Proxy whenever it's
available).
Notes:
To use the Proxy Redundancy mechanism, you need to enable the
keep-alive with Proxy option, by setting the parameter
EnableProxyKeepAlive to 1 or 2.
If this parameter is configured, then the global parameter is ignored.

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
CategoryGateway
Analog Ports8 FXS ports
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
ProtocolsSIP, MGCP, H.323
ModelAudioCodes MediaPack MP-118
Fax SupportT.38
ManagementWeb-based, SNMP, CLI
SecuritySRTP, TLS, HTTPS
Power SupplyAC 100-240V, 50-60Hz
Humidity10% to 90%, non-condensing
Network Interfaces2 x 10/100Base-T Ethernet