User's Manual 446 Document #: LTRT-65422
MP-11x & MP-124
Parameter Description
[BootPDelay]
Defines the interval between the device's startup and the first
BootP/DHCP request that is issued by the device.
[1] = (Default) 1 second
[2] = 3 second
[3] = 6 second
[4] = 30 second
[5] = 60 second
Note: For this parameter to take effect, a device reset is required.
[ExtBootPReqEnable]
Determines whether the device uses the Vendor Specific Information
field in the BootP request to provide device-related initial startup
information.
[0] = (Default) Disabled.
[1] = Enables extended information to be sent in BootP requests. The
device uses the Vendor Specific Information field in the BootP
request to provide device-related initial startup information such as
device type, current IP address, software version. For a full list of the
Vendor Specific Information fields, refer to the AcBootP Utility User's
Guide. The AcBootP utility displays this information in the 'Client Info'
column.
Notes:
For this parameter to take effect, a device reset is required.
This option is not available on DHCP servers.
43.4 Security Parameters
This subsection describes the device's security parameters.
43.4.1 General Parameters
The general security parameters are described in the table below.
Table 43-20: General Security Parameters
Parameter Description
Web: Voice Menu
Password
[VoiceMenuPassword]
Defines the password for accessing the device's FXS Voice menu used for
configuring and monitoring the device.
The default is 12345.
Notes:
To activate the menu, connect a POTS telephone to an FXS port and
dial *** (three stars) followed by the password.
To disable the Voice menu, do any of the following:
Set the VoiceMenuPassword parameter to 'disable'.
Change the Web login password for the Admin user from its default
value (i.e., 'Admin') to any other value, and then reset the device.
This parameter is applicable only to FXS interfaces.
For more information on the Voice menu, see FXS Voice Menu
Guidance on page 29.

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
CategoryGateway
Analog Ports8 FXS ports
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
ProtocolsSIP, MGCP, H.323
ModelAudioCodes MediaPack MP-118
Fax SupportT.38
ManagementWeb-based, SNMP, CLI
SecuritySRTP, TLS, HTTPS
Power SupplyAC 100-240V, 50-60Hz
Humidity10% to 90%, non-condensing
Network Interfaces2 x 10/100Base-T Ethernet