Parameter Description
[CurrentDisconnectDefaultThreshold]
Defines the line voltage threshold at which a current
disconnect detection is considered.
The valid range is 0 to 20 Volts. The default is 4 Volts.
Notes:
ï‚§ This parameter is applicable only to FXO interfaces.
ï‚§ For this parameter to take effect, a device reset is
required.
[TimeToSampleAnalogLineVoltage]
Defines the frequency at which the analog line voltage is
sampled (after offhook), for detection of the current
disconnect threshold.
The valid range is 100 to 2500 msec. The default is 1000
msec.
Notes:
ï‚§ This parameter is applicable only to FXO interfaces.
ï‚§ For this parameter to take effect, a device reset is
required.
43.10.7 Tone Parameters
This subsection describes the device's tone parameters.
43.10.7.1 Telephony Tone Parameters
The telephony tone parameters are described in the table below.
Table 43-52: Tone Parameters
Parameter Description
Web: SIP Hold Behavior
[SIPHoldBehavior]
Enables the device to handle incoming re-INVITE messages
with the "a=sendonly" attribute in the SDP, in the same way
as if an "a=inactive" is received in the SDP. When enabled,
the device plays a held tone to the Tel phone and responds
with a SIP 200 OK containing the "a=recvonly" attribute in the
SDP.
ï‚§ [0] Disable (default)
ï‚§ [1] Enable
Web/EMS: Dial Tone Duration [sec]
[TimeForDialTone]
Defines the duration (in seconds) that the dial tone is played.
FXS interfaces play the dial tone after the phone is picked up
(off-hook). FXO interfaces play the dial tone after the port is
seized in response to ringing (from PBX/PSTN).
The valid range is 0 to 60. The default time is 16.
Notes:
ï‚§ During play of dial tone, the device waits for DTMF digits.
ï‚§ This parameter is not applicable when Automatic Dialing is
enabled.
Web/EMS: Stutter Tone Duration
[StutterToneDuration]
Defines the duration (in msec) of the confirmation tone. A
stutter tone is played (instead of a regular dial tone) when a
Message Waiting Indication (MWI) is received. The stutter