Version 6.6 549 MP-11x & MP-124
User's Manual 43. Configuration Parameters Reference
Parameter Description
(applicable to FXO interfaces):
SITDetectorEnable = 1
UserDefinedToneDetectorEnable = 1
DisconnectOnBusyTone = 1 (applicable for busy, reorder,
and SIT tones)
Note: For this parameter to take effect, a device reset is
required.
EMS: UDT Detector Frequency
Deviation
[UDTDetectorFrequencyDeviation]
Defines the deviation (in Hz) allowed for the detection of each
signal frequency.
The valid range is 1 to 50. The default is 50.
Note: For this parameter to take effect, a device reset is
required.
EMS: CPT Detector Frequency
Deviation
[CPTDetectorFrequencyDeviation]
Defines the deviation (in Hz) allowed for the detection of each
CPT signal frequency.
The valid range is 1 to 30. The default is 10.
Note: For this parameter to take effect, a device reset is
required.
43.10.7.3 Metering Tone Parameters
The metering tone parameters are described in the table below.
Table 43-54: Metering Tone Parameters
Parameter Description
Web: Generate Metering
Tones
EMS: Metering Mode
[PayPhoneMeteringMode]
Determines the method used to configure the metering tones that are
generated to the Tel side.
[0] Disable = (Default) Metering tones aren't generated.
[1] Internal Table = Metering tones are generated according to the
device's Charge Code table (using the ChargeCode parameter).
Notes:
This parameter is applicable only to FXS interfaces.
If you select 'Internal Table', you must configure the Charge Codes
table, using the ChargeCode parameter (see Configuring Charge
Codes Table on page 263).
Web: Analog Metering
Type
EMS: Metering Type
[MeteringType]
Determines the metering method for generating pulses (sinusoidal
metering burst frequency) by the FXS port.
[0] 12 KHz = (Default) 12 kHz sinusoidal bursts.
[1] 16 KHz = 16 kHz sinusoidal bursts.
[2] = Polarity Reversal pulses.
Notes:
For this parameter to take effect, a device reset is required.
This parameter is applicable only to FXS interfaces.

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
CategoryGateway
Analog Ports8 FXS ports
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
ProtocolsSIP, MGCP, H.323
ModelAudioCodes MediaPack MP-118
Fax SupportT.38
ManagementWeb-based, SNMP, CLI
SecuritySRTP, TLS, HTTPS
Power SupplyAC 100-240V, 50-60Hz
Humidity10% to 90%, non-condensing
Network Interfaces2 x 10/100Base-T Ethernet