Version 6.6 431 MP-11x & MP-124
User's Manual 43. Configuration Parameters Reference
43.2 Management Parameters
This subsection describes the device's Web and Telnet parameters.
43.2.1 General Parameters
The general management parameters are described in the table below.
Table 43-10: General Management Parameters
Parameter Description
Web: Web and Telnet
Access List Table
EMS: Web Access
Addresses
[WebAccessList_x]
This table configures up to ten IP addresses that are permitted to access
the device's Web interface and Telnet interfaces. Access from an
undefined IP address is denied. When no IP addresses are defined in
this table, this security feature is inactive (i.e., the device can be
accessed from any IP address).
The default is 0.0.0.0 (i.e., the device can be accessed from any IP
address).
For example:
WebAccessList_0 = 10.13.2.66
WebAccessList_1 = 10.13.77.7
For a description of this parameter, see 'Configuring Web and Telnet
Access List' on page 70.
43.2.2 Web Parameters
The Web parameters are described in the table below.
Table 43-11: Web Parameters
Parameter Description
Web: Password Change Interval
[WebUserPassChangeInterval]
Defines the duration (in minutes) of the validity of Web login
passwords. When this duration expires, the password of the
Web user must be changed.
The valid value is 0 to 100000, where 0 means that the
password is always valid. The default is 1140.
Note: This parameter is applicable only when using the Web
Users table, where the default value of the 'Password Age'
parameter in the Web Users table inherits this parameter's
value.
Web: User inactivity timer
[UserInactivityTimer]
Defines the duration (in days) for which a user has not logged in
to the Web interface, after which the status of the user becomes
inactive and can no longer access the Web interface. These
users can only log in to the Web interface if their status is
changed (to New or Valid) by a System Administrator or Master
user.
The valid value is 0 to 10000, where 0 means inactive. The
default is 90.
Note: This parameter is applicable only when using the Web
Users table.
Web: Session Timeout Defines the duration (in minutes) of Web inactivity of a logged-in

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-118
CategoryGateway
LanguageEnglish

Related product manuals