User's Manual 430 Document #: LTRT-65422
MP-11x & MP-124
Parameter Description
Web: NTP Secondary Server
IP
[NTPSecondaryServerIP]
Defines a second NTP server's address as an FQDN or an IP
address (in dotted-decimal notation). This NTP is used for
redundancy; if the primary NTP server fails, then this NTP server is
used.
The default IP address is 0.0.0.0.
Web: NTP UTC Offset
EMS: UTC Offset
[NTPServerUTCOffset]
Defines the Universal Time Coordinate (UTC) offset (in seconds)
from the NTP server.
The default offset is 0. The offset range is -43200 to 43200.
Web: NTP Update Interval
EMS: Update Interval
[NTPUpdateInterval]
Defines the time interval (in seconds) that the NTP client requests
for a time update.
The default interval is 86400 (i.e., 24 hours). The range is 0 to
214783647.
Note: It is not recommend to set this parameter to beyond one
month (i.e., 2592000 seconds).
Daylight Saving Time Parameters
Web: Day Light Saving Time
EMS: Mode
[DayLightSavingTimeEnable]
Enables daylight saving time.
ï‚§ [0] Disable (default)
ï‚§ [1] Enable
Web: Start Time or Day of
Month Start
EMS: Start
[DayLightSavingTimeStart]
Defines the date and time when daylight saving begins. This value
can be configured using any of the following formats:
ï‚§ Day of year - mm:dd:hh:mm, where:
dd denotes date of the month
mm denotes minutes
For example, "05:01:08:00" denotes daylight saving starting from
May 1 at 8 A.M.
ï‚§ Day of month - mm:day/wk:hh:mm, where:
mm denotes month (e.g., 04)
day denotes day of week (e.g., FRI)
wk denotes week of the month (e.g., 03)
hh denotes hour (e.g., 23)
mm denotes minutes (e.g., 10)
For example, "04:FRI/03:23:00" denotes Friday, the third week of
April, at 11 P.M. The week field can be 1-5, where 5 denotes the
last occurrence of the specified day in the specified month. For
example, "04:FRI/05:23:00" denotes the last Friday of April, at 11
P.M.
Web: End Time or Day of
Month End
EMS: End
[DayLightSavingTimeEnd]
Defines the date and time when daylight saving ends. For a
description of the format of this value, see the
DayLightSavingTimeStart parameter.
Web/EMS: Offset
[DayLightSavingTimeOffset]
Defines the daylight saving time offset (in minutes).
The valid range is 0 to 120. The default is 60.