However, in cases of heavy traffic, option 7 is recommended.
ï‚§ Options 2, 3, 4, and 6 are not recommended.
Web: Syslog Facility Number
EMS: SyslogFacility
[SyslogFacility]
Defines the Facility level (0 through 7) of the device’s Syslog
messages, according to RFC 3164. This allows you to identify Syslog
messages generated by the device. This is useful, for example, if you
collect the device’s and other equipments’ Syslog messages, at one
single server. The device’s Syslog messages can easily be identified
and distinguished from other Syslog messages by its Facility level.
Therefore, in addition to filtering Syslog messages according to IP
address, the messages can be filtered according to Facility level.
ï‚§ [16] = (Default) local use 0 (local0)
ï‚§ [17] = local use 1 (local1)
ï‚§ [18] = local use 2 (local2)
ï‚§ [19] = local use 3 (local3)
ï‚§ [20] = local use 4 (local4)
ï‚§ [21] = local use 5 (local5)
ï‚§ [22] = local use 6 (local6)
ï‚§ [23] = local use 7 (local7)
Web: Activity Types to
Report via Activity Log
Messages
[ActivityListToLog]
Defines the Activity Log mechanism of the device, which sends log
messages to a Syslog server for reporting certain types of Web
operations according to the below user-defined filters.
ï‚§ [pvc] Parameters Value Change = Changes made on-the-fly to
parameters. Note that the ini file parameter,
EnableParametersMonitoring can also be used to set this option,
using values [0] (disable) or [1] (enable).
ï‚§ [afl] Auxiliary Files Loading = Loading of auxiliary files.
ï‚§ [dr] Device Reset = Reset of device via the 'Maintenance Actions
page.
Note: For this option to take effect, a device reset is required.
ï‚§ [fb] Flash Memory Burning = Burning of files or parameters to flash
(in 'Maintenance Actions page).
ï‚§ [swu] Device Software Update = cmp file loading via the Software
Upgrade Wizard.
ï‚§ [ard] Access to Restricted Domains = Access to restricted
domains, which include the following Web pages: