EasyManuals Logo

AudioCodes MediaPack MP-118 User Manual

AudioCodes MediaPack MP-118
584 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #497 background imageLoading...
Page #497 background image
Version 6.6 497 MP-11x & MP-124
User's Manual 43. Configuration Parameters Reference
Parameter Description
Web: Answer Detector Activity
Delay
[AnswerDetectorActivityDelay]
Defines the time (in 100-msec resolution) between activating the
Answer Detector and the time that the detector actually starts to
operate.
The valid range is 0 to 1023. The default is 0.
Web: Answer Detector Silence
Time
[AnswerDetectorSilenceTime]
Currently, not supported.
Web: Answer Detector
Redirection
[AnswerDetectorRedirection]
Currently, not supported.
Web: Answer Detector Sensitivity
EMS: Sensitivity
[AnswerDetectorSensitivity]
Defines the Answer Detector sensitivity.
The range is 0 (most sensitive) to 2 (least sensitive). The default
is 0.
Web: Silence Suppression
EMS: Silence Compression Mode
[EnableSilenceCompression]
Determines the Silence Suppression support. Silence
Suppression is a method for conserving bandwidth on VoIP calls
by not sending packets when silence is detected.
[0] Disable = (Default) Silence Suppression is disabled.
[1] Enable = Silence Suppression is enabled.
[2] Enable without Adaptation = A single silence packet is sent
during a silence period (applicable only to G.729).
Note: If the selected coder is G.729, the value of the 'annexb'
parameter of the fmtp attribute in the SDP is determined by the
following rules:
If EnableSilenceCompression is 0: 'annexb=no'.
If EnableSilenceCompression is 1: 'annexb=yes'.
If EnableSilenceCompression is 2 and IsCiscoSCEMode is 0:
'annexb=yes'.
If EnableSilenceCompression is 2 and IsCiscoSCEMode is 1:
'annexb=no'.
Note: This parameter can also be configured in an IP Profile.
Web: Echo Canceler
EMS: Echo Canceller Enable
[EnableEchoCanceller]
Enables echo cancellation (i.e., echo from voice calls is
removed).
[0] Disable
[1] Enable (default)
Note: This parameter can also be configured in an IP Profile
and/or a Tel Profile.
EMS: Echo Canceller Hybrid
Loss
[ECHybridLoss]
Defines the four-wire to two-wire worst-case Hybrid loss, the ratio
between the signal level sent to the hybrid and the echo level
returning from the hybrid.
[0] = (Default) 6 dB
[1] = N/A
[2] = 0 dB
[3] = 3 dB
EMS: ECN lp Mode
[ECNLPMode]
Defines the echo cancellation Non-Linear Processing (NLP)
mode.
[0] = (Default) NLP adapts according to echo changes
[1] = Disables NLP

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
CategoryGateway
Analog Ports8 FXS ports
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
ProtocolsSIP, MGCP, H.323
ModelAudioCodes MediaPack MP-118
Fax SupportT.38
ManagementWeb-based, SNMP, CLI
SecuritySRTP, TLS, HTTPS
Power SupplyAC 100-240V, 50-60Hz
Humidity10% to 90%, non-condensing
Network Interfaces2 x 10/100Base-T Ethernet