User's Manual 43. Configuration Parameters Reference
Parameter Description
When using an external conference server (options [0] or
[1]), a conference call with up to six participants can be
established.
For local, on-board three-way conferencing (option [2]) on
MP-112, the following additional parameter settings must
be made:
EnableIPMediaChannels = 1
[ IPMediaChannels ]
FORMAT IPMediaChannels_Index =
IPMediaChannels_ModuleID,
IPMediaChannels_DSPChannelsReserved;
IPMediaChannels 0 = 1, 2;
[ \IPMediaChannels ]
Web: Max 3 Way Conference
EMS: Max In Board Calls
[MaxInBoardConferenceCalls]
Defines the maximum number of simultaneous, on-board
three-way conference calls.
The valid range is 0 to 2. The default is 2.
Notes:
For enabling on-board, three-way conferencing, use the
3WayConferenceMode parameter.
This parameter is applicable only to FXS interfaces.
Web: Three Way Conference Non
Allocatable Ports
EMS: Non Allocateable Port Number
[3WayConfNoneAllocateablePorts]
Defines the ports that are not allocated as resources for on-
board three-way conference calls that are initiated by other
ports. Ports that are not configured with this parameter (and
that are idle) are used by the device as a resource for
establishing these type of conference calls.
The valid range is up to 8 ports. To add a range of ports, use
the comma separator. For example, for not allowing the use of
ports 2, 4 and 8 as resources, enter the following value: 2,4,8.
The order of the entered values is not relevant (i.e., the
example above can be entered as 8,2,4). The default is 0.
Notes:
To enable on-board, three-way conferencing, use the
3WayConferenceMode and MaxInBoardConferenceCalls
parameters.
This parameter is applicable only to FXS interfaces.
Web: Establish Conference Code
EMS: Establish Code
[ConferenceCode]
Defines the DTMF digit pattern, which upon detection
generates the conference call when three-way conferencing is
enabled (Enable3WayConference is set to 1).
The valid range is a 25-character string. The default is “!”
(Hook-Flash).
Note: If the FlashKeysSequenceStyle parameter is set to 1 or
2, the setting of the ConferenceCode parameter is overridden.
Web/EMS: Conference ID
[ConferenceID]
Defines the Conference Identification string.
The valid value is a string of up to 16 characters. The default
is "conf".
The device uses this identifier in the conference-initiating
INVITE that is sent to the media server when the
Enable3WayConference parameter is set to 1.
Web: Use Different RTP port After
Hold
Enables the use of different RTP ports for the two calls
involved in a three-way conference call made by the FXS

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
CategoryGateway
Analog Ports8 FXS ports
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
ProtocolsSIP, MGCP, H.323
ModelAudioCodes MediaPack MP-118
Fax SupportT.38
ManagementWeb-based, SNMP, CLI
SecuritySRTP, TLS, HTTPS
Power SupplyAC 100-240V, 50-60Hz
Humidity10% to 90%, non-condensing
Network Interfaces2 x 10/100Base-T Ethernet