Parameter Description
broken RTP connection.
During a call, if the source IP address (from where the
RTP packets are received) is changed without notifying
the device, the device filters these RTP packets. To
overcome this, set the DisconnectOnBrokenConnection
parameter to 0; the device doesn't detect RTP packets
arriving from the original source IP address and
switches (after 300 msec) to the RTP packets arriving
from the new source IP address.
This parameter can also be configured in an IP Profile.
Web: Broken Connection Timeout
EMS: Broken Connection Event
Timeout
[BrokenConnectionEventTimeout]
Defines the time period (in 100-msec units) after which a
call is disconnected if an RTP packet is not received.
The valid range is from 3 (i.e., 300 msec) to an unlimited
value (e.g., 20 hours). The default is 100 (i.e., 10000 msec
or 10 seconds).
Notes:
This parameter is applicable only if the parameter
DisconnectOnBrokenConnection is set to 1.
Currently, this feature functions only if Silence
Suppression is disabled.
Web: Disconnect Call on Silence
Detection
EMS: Disconnect On Detection Of
Silence
[EnableSilenceDisconnect]
Determines whether calls are disconnected after detection
of silence.
[1] Yes = The device disconnects calls in which silence
occurs (in both call directions) for more than a user-
defined time.
[0] No = (Default) Call is not disconnected when silence
is detected.
The silence duration can be configured by the
FarEndDisconnectSilencePeriod parameter (default 120).
Note: To activate this feature, set the parameters
EnableSilenceCompression and
FarEndDisconnectSilenceMethod to 1.
Web: Silence Detection Period [sec]
EMS: Silence Detection Time Out
[FarEndDisconnectSilencePeriod]
Defines the duration of the silence period (in seconds) after
which the call is disconnected.
The range is 10 to 28,800 (i.e., 8 hours). The default is 120
seconds.
Note: For this parameter to take effect, a device reset is
required.
Web: Silence Detection Method
[FarEndDisconnectSilenceMethod]
Determines the silence detection method.
[0] None = Silence detection option is disabled.
[1] Packets Count = According to packet count.
[2] Voice/Energy Detectors = (Default) According to
energy and voice detectors.
[3] All = According to packet count, and energy and
voice detectors.
Note: For this parameter to take effect, a device reset is
required.
[FarEndDisconnectSilenceThreshold]
Defines the threshold of the packet count (in percentages)
below which is considered silence by the device.
The valid range is 1 to 100%. The default is 8%.

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
CategoryGateway
Analog Ports8 FXS ports
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
ProtocolsSIP, MGCP, H.323
ModelAudioCodes MediaPack MP-118
Fax SupportT.38
ManagementWeb-based, SNMP, CLI
SecuritySRTP, TLS, HTTPS
Power SupplyAC 100-240V, 50-60Hz
Humidity10% to 90%, non-condensing
Network Interfaces2 x 10/100Base-T Ethernet