User's Manual 582 Document #: LTRT-65422
MP-11x & MP-124
Function Specification
Capacity
Registered Users
25
Signaling
Signaling
MP-112: FXS Loop-start
MP-114 & MP-118: FXS, FXO Loop-start
MP-124: FXS Loop-start
In-band Signaling
DTMF (TIA 464B)
User-defined and call progress tones
Out-of-Band Signaling
DTMF Relay (RFC 2833), DTMF via SIP INFO
Control
SIP (RFC 3261)
Provisioning
Protocols
BootP, DHCP, TFTP and HTTP for Automatic Installation
DHCP options 66,67 in auto update mode
Remote management using Web browser
EMS (Element Management System) / SNMP V3
Syslog support
RS-232 for basic configuration (via CLI)
Voice Menu using touch-tone phone (FXS interface) for basic
configuration
Security
Media
SRTP
Control
H.235, IPSec, TLS/SIPS
Management
HTTPS, Access List, IPSec
Physical
Power
Single universal power supply 100-240V 0.3A max. 50-60 Hz or -48V
DC
Note: -48V DC is supported only on MP-124D.
Environmental
Operational: 5 to 40°C (41 to 104°F)
Storage: -25 to 85°C (-13 to 185°F)
Humidity: 10 to 90% non-condensing
Dimensions
MP-112: 42 x 172 x 220 mm
MP-114 & MP-118: 42 x 172 x 220 mm
MP-124: 44 x 445 x 269 mm
Weight
MP-1xx: 0.5 kg (1.1 lbs.) approx.
MP-124: 1.8 kg (4 lbs.)
Mounting
Rack mount, Table top, Wall mount
Additional Features
Message Waiting Indication
Applying 100V DC online for lighting bulb in handset, FSK, Stutter
Dial Tone
High Availability
PSTN Fallback:
Support of PSTN fallback due to Power failure, if the
IP connection is down or due to customer defined IP QoS thresholds
Stand Alone Survivability (SAS):
Supports SAS of up to 25 SIP

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
CategoryGateway
Analog Ports8 FXS ports
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
ProtocolsSIP, MGCP, H.323
ModelAudioCodes MediaPack MP-118
Fax SupportT.38
ManagementWeb-based, SNMP, CLI
SecuritySRTP, TLS, HTTPS
Power SupplyAC 100-240V, 50-60Hz
Humidity10% to 90%, non-condensing
Network Interfaces2 x 10/100Base-T Ethernet