5.3.4 Signal range at the analogue output 1: view/edit 33
5.3.5 Feedback signals (configuration) via analogue output 2: view 34
5.3.6 Signal range at the analogue output 2: view/edit 34
6 Operation mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.1 Operation mode OFF 35
6.2 Operation mode LOCAL 36
6.2.1 Push-to-run operation or self-retaining: set for operation mode LOCAL 36
6.3 Operation mode REMOTE 37
6.3.1 Push-to-run operation or self-retaining: set for operation mode REMOTE 37
6.4 Operation mode EMERGENCY 38
6.4.1 Operation mode (type of duty) activation for an EMERGENCY operation 38
6.4.2 EMERGENCY operation: switch on or off/signal behaviour definition 39
6.4.3 Actuator behaviour definition in case of an EMERGENCY operation 39
6.4.4 EMERGENCY position definition 40
6.4.5 Motor protection and/or torque switching: by-pass 40
6.5 Operation mode FAILURE 41
6.5.1 Failure behaviour: switch on or off 41
6.5.2 Source for initiation (failure source): set for failure operation 42
6.5.3 Actuator reaction (failure position): set on loss of signal 42
6.5.4 Preset position definition 43
6.5.5 Failure delay time setting 43
6.5.6 Failure behaviour on bus communication loss 44
7 Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
7.1 Type of seating: check/edit end positions 45
7.2 Torque switching: check/set 46
7.3 Limit switching setting 47
7.4 Intermediate positions (option) 48
7.4.1 Display indication: enable view 48
7.4.2 Intermediate positions: switch on or off 49
7.4.3 Intermediate position definition 49
7.4.4 Operation behaviour = actuator behaviour definition 50
7.4.5 Intermediate positions: set the signalling 50
7.5 Intermediate positions with multiport valve function (option) 52
7.5.1 Check: Multiport valve function availablequestion 52
7.5.2 Check: Positioner active? 53
7.5.3 Display indication: enable view 53
7.5.4 Intermediate positions: switch on or off 53
7.5.5 Intermediate position setting 53
7.5.6 Operation behaviour = actuator behaviour definition 54
7.5.7 Intermediate positions signalling 54
7.5.8 Intermediate positions in LOCAL: direct approach without stopping 54
7.6 Positioner (operation mode SETPOINT MODE) 55
7.6.1 Adaptive behaviour: switch on or off 55
7.6.2 Overrun (inner dead band): set manually 56
7.6.3 Max. error variable (outer dead band): set manually 57
7.6.4 Dead time setting 57
7.6.5 Closing fully/opening fully (end position tolerance for setpoint E1) 58
7.6.6 Open-close duty (REMOTE MODE) and modulating duty (SETPOINT MODE) selection 58
7.6.7 Source of setpoint E1: view 59
7.6.8 Input range of setpoint 1: view/edit 60
7.7 Process controller (option) 61
7.7.1 Setting procedure 62
7.7.2 Process controller activation (Check: Process controller available?) 62
7.7.3 Proportional gain Kp setting 63
7.7.4 Reset time Ti setting 63
7.7.5 Rate time Td setting 64
3
Actuator controls
Manual AUMATIC AC 01.1/ACExC 01.1 Profibus DP

Table of Contents

Other manuals for AUMA Aumatic AC 01.1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUMA Aumatic AC 01.1 and is the answer not in the manual?

AUMA Aumatic AC 01.1 Specifications

General IconGeneral
BrandAUMA
ModelAumatic AC 01.1
CategoryControl Unit
LanguageEnglish

Related product manuals