Maintenance Manual
E4.08.04
Issue date: 14-Dec-2015
Page: 05-14
05-50-06 High Engine Oil Consumption Inspection
Inspect engine for oil leakage.
Inspect the compression.
Analyse EECU data using the AE 300 Wizard to detect root cause.
If the root cause cannot be found, the engine has to be replaced.
05-50-07 Engine Oil System Contaminated
Analyse engine oil sample by suitable laboratory (e.g. Oelcheck GmbH).
Analyse EECU data using the AE 300 Wizard to detect root cause.
If the root cause cannot be found, the engine has to be replaced.
05-50-08 Engine Oil Pressure Loss Inspection
Check Oil quantity.
Inspect if neg. g flights have been conducted. (Visual inspection of the
breather outlet for oil contamination).
Analyse EECU data using the AE 300 Wizard to detect root cause.
If the root cause cannot be found, the engine has to be replaced.
05-50-09 Inability to Start the Engine
Check voltage.
Check battery condition.
Check fuel supply.
Check for EECU cautions.
Analyse EECU data using the AE 300 Wizard to detect root cause.
If the root cause cannot be found, the engine has to be replaced.

Table of Contents