7-50
Chapter 7. PARAMETER SETUP
No. Item Code Item
Factory
Setting
User
Setting
Setting
55
C
5
5
PARA
assignment
item 1
1000 1000 to 5000
[Note]
To set the No., add the No. of the item
to be assigned to
PARA
to the following
values for the setting group contain-
ing that item.
•1000:Constant-valueoperationdata
•1500:PIDparameter
•2500:Variableparameter
•3500:Eventcongurationdata
•4000:Tabledata
•4500:Setupdata
Assignments to which a nonexistent
No. have been set are invalid.
56
C
5
6
PARA
assignment
item 2
1000
57
C
5
7
PARA
assignment
item 3
1000
58
C
5
8
PARA
assignment
item 4
1000
59
C
5
9
PARA
assignment
item 5
1000
60
C
6
0
PARA
assignment
item 6
1000
61
C
6
1
PARA
assignment
item 7
1000
62
C
6
2
PARA
assignment
item 8
1000
63
C
6
3
Operation comple-
tion state
0 0: READY
1: END
64
C
6
4
Program time unit 0 0: h/min
1: min/s
2: 0.1s
65
C
6
5
Time display 0 0: Remaining segment time
1: Total operation time
[Note]
The total operation time returns to 0 in
the READY mode.
66
C
6
6
PV display 0 0: ON
1: OFF
2: ON
3: OFF
[Note]
Settings 0 and 2, and 1 and 3 mean the
same, respectively.
67
C
6
7
Alarm display 0: Display ON
1: Display OFF
[Note]
Even when set to 1, alarm-related
events do not operate.