Technical data • Entire device
Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
2.13.7 Status LEDs CAN / X2X (only APC620 embedded)
2.13.8 POWERLINK (only APC620 embedded)
Driver support
The fieldbus interface POWERLINK is only supported together with Automation Runtime.
Status / Error LED
The status/error LED is a green/red dual LED. The color green (status) is superimposed on the
color red (error).
Status LEDs CAN / X2X (only APC620 embedded)
Yellow LED for On Off
CAN Sends data Receives data
X2X Sends data Receives data
Table 36: Status LEDs CAN / X2X (only APC620 embedded)
POWERLINK (only APC620 embedded)
Controller
Cabling S/STP (Cat5e)
Transfer rate
Cable length max. 100 m (min. Cat5e)
LED color On Off
Green/red see Status / Error LED
Green Link
(POWERLINK
network
connection
available)
Activity (blinking)
(Data transfer in
progress)
Table 37: POWERLINK (only APC620 embedded)
Red - error Description
On The POWERLINK interface has encountered an error (failed Ethernet frames, increased number of
collisions on the network, etc.).
Table 38: Status / Error LED as error LED - POWERLINK V2 operating mode
green/red
green
Status/Error LED