EasyManua.ls Logo

B&R Automation PC 620 - SDL Flex Cable - Test Description; Torsion; Test Structure; Test Conditions

B&R Automation PC 620
594 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Standards and certifications • SDL flex cable - test description
Section 5
Standards and
certifications
407Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
9. SDL flex cable - test description
9.1 Torsion
9.1.1 Test structure
9.1.2 Test conditions
Distance a: 450 mm
Rotation angle:
±85°
Velocity: 50 cycles / minute
Special feature: The cable was clamped down twice in the machine.
9.1.3 Individual tests
Visible pixel errors: At the beginning of the test, the minimum equalizer setting was
determined. This is the value between 0-15 at which no more pixel errors are visible. If
the equalizer setting is changed due to the mechanical load, this is noted.
Touch screen for function (with a 21.3" Automation Panel - 5AP920.2138-01)
USB mouse function
Hot plug function tested by unplugging the USB plug
After a test duration of 15000 cycles, the test was ended with a result of "OK".
Figure 179: Test structure - torsion
1 ... Angle of rotatio
2 ... Fixed
3 ... Movable
1
a
2
3

Table of Contents

Related product manuals