76
Technical data • Entire device
Automation PC 620 with 945GME N270 CPU board User's Manual V 1.10
2.6.1 Maximum ambient temperature
Figure 23: Ambient temperatures for systems with an X945 CPU board
30/40
45
-/30
40
Sensor(s) in
these locations
Without fan kit
95
Add-on drive
On-Board CompactFlash
5AC600.CFSI-00
5AC600.HDDI-00 (24-hour / standard)
5AC600.FDDS-00
Slide-in drive
Main memory
5MMDDR.0512-01
5MMDDR.1024-01
5MMDDR.2048-01
System units
5PC600.SX01-00
5PC600.SX02-00 / -01
5PC600.SX05-00 / -01
5AC600.CANI-00
5AC600.485I-00
Maximum ambient temperature
5AC600.SDL0-00
1)
1)
5PC600.X945-00
N270
50
1
2
45/55
80
80
50
-
-
-
-
-
-
95
95
95
I/O
Slide-in drive 1 and 2
Power supply
3
What can still be operated at maximum ambient
temperature and what limits are there?
Temperature limits
-
5AC600.HDDI-05 80
5PC600.SF03-00
All temperatures in °C
at 500 m above sea level.
Derating of the maximum
ambient temperature typically 1°C
per 1000 m after 500 m above sea level.
5AC600.HDDI-06
80
5ACPCI.RAIC-03 (24-hour / standard)
With fan kit
5PC600.X945-00
N270
55
1
Additional insert cards
Interfaces / AP Link
1) 24 house operation = 732 POH (Power On Hours) per month, standard operation = 250 POH or
333 POH (Power On Hours) per month.
1)